PET3CW40000H3Drop-in equivalent of 3CW40000H3
Water Cooled Triode For Industrial RF Heating
Manufactured in India, in a world-class facility equipped with high quality machinery, materials and components sourced from reputed suppliers in America, Europe and Japan. Data Sheet of 3CW40000H3 / PET3CW40000H33CW40000H3 is a water-cooled, ceramic-metal power triode with a robust mesh filament, for use in industrial radio-frequency heating.
Electrical Characteristics of 3CW40000H3 Filament . . . . . Thoriated tungsten Filament voltage (see note 1) . . . 10.0 V Filament current . . . . 160 A Surge Filament current (peak) (see note 2) . 800 A Filament cold resistance . . . . 6.8 mΩ Peak usable cathode current . . . 50 A Amplification factor . . . . 20 Inter – electrode capacitances: Grid to anode . . . . . 46 pF Grid to filament . . . . 77 pF Anode to filament . . . . 2.1 pF Mechanical Characteristics of 3CW40000H3 Connections . . . . . Filament leads and grid contact flanges Operating position . . . . Vertical, either way up Maximum operating temperature . . 250 OC Maximum dimensions . . . . See outline drawing Net weight . . . . . 5 kg (11 pounds) approx Accessories Water coupling, supplied with CW40000H3 . WPA323A Thermal fuse available for CW40000H3 . PA85E Cathode connector . . . . PA830 For frequencies above 2MHz, CWPA830 should be used in conjunction with a strip connection to provide a low inductance cathode return. Cooling Anode of 3CW40000H3 is cooled by circulating water through the removable anode water jacket. The table lists the minimum water flow requirement for adequate anode cooling at various anode dissipation levels. In all cases, the outlet water temperature must not exceed 70 ⁰C nor should inlet water pressure exceed 60 psi. This table is based upon 20 ⁰C temperature rise. Additional forced-air cooling of 3CW40000H3 tube base is also required to maintain ceramic-to-metal seal temperature below the 250 ⁰C maximum. Approximately 50 ft3/min of cooling air directed into the base structure will generally satisfy requirements. Minimum Water Cooling Requirements of 3CW40000H3 Anode Water Pressure Dissipation Flow Drop (kW) l/min (psi) 30 22 4.5 35 25 5.0 40 29 5.5 45 32 6.0 Radio Frequency Oscillator For Industrial Service (Class C conditions, one tube) Maximum Ratings (Absolute Values) Frequency . . . . . 90 MHz max Anode voltage d.c. . . . . 12 kV max Anode current d.c.(see note 3) . . 8.0 A max Anode input power . . . 80 kW max Anode dissipation . . . 20 kW max Grid voltage d.c. . . . –2000 V max Grid current d.c. .(See note 4) . . 1.5 A max Grid dissipation . . . . 750 W max Cathode current d.c. . . . 10.0 A max Typical Operating Conditions Frequency . . . . 30 30 MHz Anode voltage d.c. . . . 7.5 10.0 kV Anode current d.c. . . . 8.0 7.9 A Anode dissipation . . . 9 14 kW Grid voltage d.c. . . . - 800 –900 V Grid resistor . . . . 570 1130 Ω Grid current d.c. . . . . 1.4 0.8 mA Grid dissipation . . . . 560 296 W Drive power . . . . 1670 960 W Anode input power . . . 60 79 kW Anode output power . . . 51 65 kW Output power less drive . . 49.3 64 kW NOTES
|